Manufacturer
Monteris Medical,NeuroBlate System
Country / Region:United States (US)Submission type:Special
Product code GEX· 21 CFR 878.4810
Product code
GEX
21 CFR 878.4810
Device details
FDA 510(k) registration fields
- K number
- K143457
- Device name
- NeuroBlate System
- Company
- Monteris Medical,
- Country / Region
- United States(US)
- Product code
- GEX
- Device class
- Class 2
- Regulation number
- 21 CFR 878.4810
- Date received
- 2014-12-03
- Decision date
- 2015-02-19
- Submission type
- Special
- Technology type
- Other(AI inferred)
- Clinical applications
- Surgical cutting
- Primary application
- Surgical cutting
- Classification source
- AI classified
Intended Use
The Monteris Medical NeuroBlate™ System is indicated for use to ablate, necrotize, or coagulate soft tissue through interstitial irradiation or thermal therapy in medicine and surgery in the discipline of neurosurgery with 1064 nm lasers. The Monteris Medical NeuroBlate™ System is intended for planning and monitoring thermal therapies under MRI visualization. It provides MRI based trajectory planning assistance for the stereotaxic placement of MRI compatible (conditional) NeuroBlate™ Laser Delivery Probes. It also provides real-time thermographic analysis of selected MRI images. When interpreted by a trained physician, this System provides information that may be useful in the determination or assessment of thermal therapy. Patient management decisions should not be made solely on the basis of the NeuroBlate™ System analysis.
Device Description
The Monteris NeuroBlate™ System is a collection of MRI-compatible laser devices and accessories that create an MRI guided delivery of precision thermal therapy in the practice of neurosurgery. The NeuroBlate System components consist of: Families of gas-cooled Laser Delivery Probes (Probe) (SideFire & FullFire) to deliver controlled energy to a target zone. This application includes the smaller diameter SideFire Select and FullFire Select families of Probes; Probe Drivers (Advanced Probe Driver, Robotic Probe Driver) which allow the surgeon to precisely position, stabilize and manipulate a probe, endoscope or other device within the target zone; An Interface Platform, which attaches to the MRI system patient table and provides supporting electronics for the Probe Drivers and interconnections for the Laser Delivery Probes; A System Electronics Rack and Components, which includes necessary umbilicals, cables, penetration panels, and small hardware for system mechanical, electrical, and electronic operation; and A Control Workstation including the M-Vision™ software, which includes a user interface for procedure planning, interactive monitoring of NeuroBlate™ procedures, and interfaces to the MRI and hardware subsystems. This submission adds a line of 2.2mm Reduced Diameter Probes to the existing 3.3mm diameter probes. They will be known as the SideFire Select™ and FullFire Select™ Probes.
Summary parsed at:2026-06-01 06:10:37 UTC
Predicate devices
1—
—
Not ingested
K143457 references 1 predicate/reference device
Cited as predicate
4NeuroBlate System
NeuroBlate System
NeuroBlate System
NeuroBlate System
4 submissions cite K143457 as a predicate
