Manufacturer
Adler Micromed, Inc.Adler MicroMed Laser Surgery Fibers
Country / Region:United States (US)Submission type:Traditional
Product code GEX· 21 CFR 878.4810
Product code
GEX
21 CFR 878.4810
Device details
FDA 510(k) registration fields
- K number
- K152417
- Device name
- Adler MicroMed Laser Surgery Fibers
- Company
- Adler Micromed, Inc.
- Country / Region
- United States(US)
- Product code
- GEX
- Device class
- Class 2
- Regulation number
- 21 CFR 878.4810
- Date received
- 2015-08-26
- Decision date
- 2015-12-01
- Submission type
- Traditional
- Technology type
- Other(AI inferred)
- Clinical applications
- Surgical cutting
- Primary application
- Surgical cutting
- Classification source
- AI classified
Indications for Use
The Fibers are indicated for use in general surgical applications for incision, excision, vaporization, ablation, hemostasis or coagulation of soft tissue. It is also indicated for use in open or closed endoscopic applications where incision, excision, tissue dissection, excision of external tumors and lesions, complete or partial resection of internal organs, tumors or lesions, tissue vaporization, hemostasis and or coagulation may be indicated. The Adler MicroMed Laser Surgery Fibers have a wavelength range of 450 nm to 2100 nm, can be used in contact and non-contact mode and are indicated for use in general surgery, urology, gastroenterology, gynecology, dermatology, vascular surgery, neurosurgery, plastic surgery, ENT and endovenous occlusion of the greater saphenous vein in the patient with superficial vein reflux and laser assisted lipolysis with a cleared compatible laser marketed for the mentioned intended uses and using an SMA 905 connector.
Intended Use
The Fibers are indicated for use in general surgical applications for incision, excision, vaporization, ablation, hemostasis or coagulation of soft tissue. It is also indicated for use in open or closed endoscopic applications where incision, excision, tissue dissection, excision of external tumors and lesions, complete or partial resection of internal organs, tumors or lesions, tissue vaporization, hemostasis and or coagulation may be indicated. The Adler MicroMed Laser Surgery Fibers have a wavelength range of 450 nm to 2100 nm, can be used in contact and non-contact mode and are indicated for use in general surgery, urology, gastroenterology, gynecology, dermatology, vascular surgery, neurosurgery, plastic surgery, ENT and endovenous occlusion of the greater saphenous vein in the patient with superficial vein reflux and laser assisted lipolysis with a cleared compatible laser marketed for the mentioned intended uses and using an SMA 905 connector.
Device Description
The Adler MicroMed Laser Surgery Fibers are single use laser delivery devices provided sterile and intended for medical applications in various fields of laser surgery. The devices are based on a silica quartz glass core, have a length range of 6.5 feet (2 meters) to 9.8 feet (3 meters) and a wavelength range between 450 and 2100nm. The proximal end of the fibers is connected to a cleared laser system via an SMA 905 connector, while the distal end delivers the laser energy to the target tissue in pulsed and continuous wave mode. The distal end may have a rounded or conical silica cap, or non-capped tips, which may be flat, spherical, ball, conical or bended for the various intended uses and effects.
Summary parsed at:2026-06-01 06:11:37 UTC
Predicate devices
1—
—
Not ingested
K152417 references 1 predicate/reference device
Cited as predicate
2A.R.C. Laser Surgical Fibers and Probes
BeaMed Laser Surgery Fibers
2 submissions cite K152417 as a predicate