Remi Robotic Navigation System

Fusion Robotics, LLC

Country / Region:United States (US)Submission type:Traditional

Product code OLO· 21 CFR 882.4560

Summary PDF

Company

United States (US)

Product code

OLO
21 CFR 882.4560

Predicate devices

3

Cited as predicate

0

Device details

FDA 510(k) registration fields

K number
K223350
Device name
Remi Robotic Navigation System
Country / Region
United States(US)
Product code
OLO
Device class
Class 2
Regulation number
21 CFR 882.4560
Date received
2022-11-02
Decision date
2023-03-13
Submission type
Traditional
Technology type
Robotic Navigation(AI inferred)
Clinical applications
Spine SurgeryNavigation System
Primary application
Spine Surgery
Classification source
AI classified

Indications for Use

The Remi Robotic Navigation System is intended for use as an aid for precisely locating anatomical structures and for the spatial positioning and orientation of a tool holder or guide tube to be used by surgeons for navigating and/or guiding compatible surgical instruments in open or percutaneous spinal procedures in reference to rigid patient anatomy and fiducials that can be identified on a 3D imaging scan or 2D fluoroscopic images. The Remi Robotic Navigation System is indicated for assisting the surgeon in placing pedicle screws in vertebrae in the posterior lumbar region (L1-S1). The system is designed for lumbar pedicle screw placement with the patient in the prone position and is compatible with the Accelus LineSider Spinal System.

Intended Use

The Remi Robotic Navigation System is intended for use as an aid for precisely locating anatomical structures and for the spatial positioning and orientation of a tool holder or guide tube to be used by surgeons for navigating and/or guiding compatible surgical instruments in open or percutaneous spinal procedures in reference to rigid patient anatomy and fiducials that can be identified on a 3D imaging scan or 2D fluoroscopic images. The Remi Robotic Navigation System is indicated for assisting the surgeon in placing pedicle screws in vertebrae in the posterior lumbar region (L1-S1). The system is designed for lumbar pedicle screw placement with the patient in the prone position.

Device Description

The Remi Robotic Navigation System is designed to assist in the navigation and guidance of surgical instruments during spinal procedures. It incorporates validated 2D fluoroscopic imaging systems and is compatible with the Accelus LineSider Spinal System. The system utilizes intraoperative and preoperative imaging for patient registration, surgical planning, and real-time tracking of navigated instruments.

Summary parsed at:2026-06-19 05:41:31 UTC