Dynamis Robotic Surgical System

LEM Surgical AG

Country / Region:Switzerland (CH)Submission type:Traditional

Product code OLO· 21 CFR 882.4560

Summary PDF

Company

Switzerland (CH)

Product code

OLO
21 CFR 882.4560

Predicate devices

1

Cited as predicate

0

Device details

FDA 510(k) registration fields

K number
K243326
Device name
Dynamis Robotic Surgical System
Country / Region
Switzerland(CH)
Product code
OLO
Device class
Class 2
Regulation number
21 CFR 882.4560
Date received
2024-10-24
Decision date
2025-04-23
Submission type
Traditional
Technology type
Robotic Navigation(AI inferred)
Clinical applications
Spine SurgeryNavigation System
Primary application
Spine Surgery
Classification source
AI classified

Indications for Use

The Dynamis Robotic Surgical System is intended for use as an aid for precisely locating anatomical structures and for the spatial positioning and orientation of an instrument holder or guide tube to be used by surgeons for navigating and/or guiding qualified surgical instruments in open or percutaneous procedures provided that the required fiducial markers and rigid patient anatomy can be identified on intraoperative CT scans. The Dynamis Robotic Surgical System is indicated for the placement of non-cervical spinal pedicle screws.

Intended Use

The Dynamis Robotic Surgical System is intended for use as an aid for precisely locating anatomical structures and for the spatial positioning and orientation of an instrument holder or guide tube to be used by surgeons for navigating and/or guiding qualified surgical instruments in open or percutaneous procedures provided that the required fiducial markers and rigid patient anatomy can be identified on intraoperative CT scans. The Dynamis Robotic Surgical System is indicated for the placement of non-cervical spinal pedicle screws.

Device Description

The Dynamis System is an integrated navigation-based robotic platform with real-time tracking capability for spine surgical procedures that include thoracic, lumbar, and sacral approaches. The system is comprised of two computer-controlled robotic arms to support surgical robotic guidance, while a third robotic arm holds and controls the Scout navigation camera. All components are integrated into one physical cart located partially underneath the surgical table. The Dynamis Robotic Surgical System functions as a stable platform that operates with intraoperative DICOM format images for intraoperative planning and operation. The system software is responsible for all motion, control, navigation, data storage, user management, case management, and safety functions. The navigation and guidance system establishes registration between the virtual patient (points on the patient images) and the physical patient (corresponding to the patient's bony anatomy). The information of the plan, coupled with the registration, provides the necessary information to give visual assistance to the surgeon during freehand navigation or during the robotic alignment of instruments. Navigation can also be achieved without robotic guidance with the proprietary navigation instruments provided with the Dynamis system. Dynamis is designed and intended to be used with qualified surgical instruments, which are defined as legally marketed instruments that meet pre-specified criteria and that pass the Instrument Setup process, which is an instrument verification test integrated into the Dynamis Robotic Surgical System.