Manufacturer
Blue Belt Technologies, Inc.REAL INTELLIGENCE™ CORI™ XT (CORI XT)
Country / Region:United States (US)Submission type:Traditional
Product code OLO· 21 CFR 882.4560
Product code
OLO
21 CFR 882.4560
Cited as predicate
0
Device details
FDA 510(k) registration fields
- K number
- K252841
- Device name
- REAL INTELLIGENCE™ CORI™ XT (CORI XT)
- Company
- Blue Belt Technologies, Inc.
- Country / Region
- United States(US)
- Product code
- OLO
- Device class
- Class 2
- Regulation number
- 21 CFR 882.4560
- Date received
- 2025-09-08
- Decision date
- 2025-12-05
- Submission type
- Traditional
- Technology type
- Stereotactic Surgery(AI inferred)
- Clinical applications
- Knee SurgeryOther
- Primary application
- Knee Surgery
- Classification source
- AI classified
Indications for Use
REAL INTELLIGENCE CORI XT (CORI XT) is intended to assist the surgeon in providing software-defined spatial boundaries for orientation and reference information to anatomical structures during orthopedic procedures. REAL INTELLIGENCE CORI is indicated for use in surgical procedures, in which the use of stereotactic surgery may be appropriate, and where reference to rigid anatomical bony structures can be determined. These procedures include: • unicondylar knee replacement (UKR), • total knee arthroplasty (TKA), • revision knee arthroplasty, • anatomic total shoulder arthroplasty (aTSA), and • reverse total shoulder arthroplasty (rTSA) • total hip arthroplasty (THA).
Intended Use
REAL INTELLIGENCE CORI XT (CORI XT) is intended to assist the surgeon in providing software-defined spatial boundaries for orientation and reference information to anatomical structures during orthopedic procedures. REAL INTELLIGENCE CORI is indicated for use in surgical procedures, in which the use of stereotactic surgery may be appropriate, and where reference to rigid anatomical bony structures can be determined.
Device Description
The subject of this Traditional 510(k) is REAL INTELLIGENCE CORI XT (CORI XT), a robotic orthopedic surgical navigation and burring system. Like its predecessor, REAL INTELLIGENCE CORI (K240139), CORI XT uses established technologies of navigation via a passive infrared tracking camera. CORI XT aids the surgeon in planning the surgical implant location and in executing the surgical plan by controlling the cutting engagement of the surgical bur. CORI XT intraoperative software controls the cutting engagement of the surgical bur based on its proximity to the planned target surface. The cutting control is achieved with two modes: Exposure control adjusts the bur's exposure with respect to a guard. Speed control regulates the signal going to the motor control module. When the surgeon encroaches on a portion of bone that is not to be cut per the surgeon's plan, the robotic system will disable cutting by retracting the bur inside the guard or by limiting the speed of the drill. Alternatively, the surgeon can disable both cutting controls and operate the robotic drill as a standard navigated surgical drill.
Summary parsed at:2026-06-19 05:25:30 UTC
Predicate devices
23—
—
Not ingested
—
—
Not ingested
—
—
Not ingested
—
—
Not ingested
—
—
Not ingested
—
—
Not ingested
—
—
Not ingested
—
—
Not ingested
—
—
Not ingested
—
—
Not ingested
—
—
Not ingested
—
—
Not ingested
—
—
Not ingested
—
—
Not ingested
—
—
Not ingested
—
—
Not ingested
ExactechGPS Total Shoulder Application, Equinoxe Planning Software
—
—
Not ingested
—
—
Not ingested
Real Intelligence™ CORI™
—
—
Not ingested
—
—
Not ingested
—
—
Not ingested
K252841 references 23 predicate/reference devices
Cited as predicate
0No later 510(k)s cite this device yet
Other submissions will appear here when they list K252841 as a predicate