REAL INTELLIGENCE™ CORI™ XT (CORI XT)

Blue Belt Technologies, Inc.

Country / Region:United States (US)Submission type:Traditional

Product code OLO· 21 CFR 882.4560

Summary PDF

Company

United States (US)

Product code

OLO
21 CFR 882.4560

Predicate devices

23

Cited as predicate

0

Device details

FDA 510(k) registration fields

K number
K252841
Device name
REAL INTELLIGENCE™ CORI™ XT (CORI XT)
Country / Region
United States(US)
Product code
OLO
Device class
Class 2
Regulation number
21 CFR 882.4560
Date received
2025-09-08
Decision date
2025-12-05
Submission type
Traditional
Technology type
Stereotactic Surgery(AI inferred)
Clinical applications
Knee SurgeryOther
Primary application
Knee Surgery
Classification source
AI classified

Indications for Use

REAL INTELLIGENCE CORI XT (CORI XT) is intended to assist the surgeon in providing software-defined spatial boundaries for orientation and reference information to anatomical structures during orthopedic procedures. REAL INTELLIGENCE CORI is indicated for use in surgical procedures, in which the use of stereotactic surgery may be appropriate, and where reference to rigid anatomical bony structures can be determined. These procedures include:
• unicondylar knee replacement (UKR),
• total knee arthroplasty (TKA),
• revision knee arthroplasty,
• anatomic total shoulder arthroplasty (aTSA), and
• reverse total shoulder arthroplasty (rTSA)
• total hip arthroplasty (THA).

Intended Use

REAL INTELLIGENCE CORI XT (CORI XT) is intended to assist the surgeon in providing software-defined spatial boundaries for orientation and reference information to anatomical structures during orthopedic procedures. REAL INTELLIGENCE CORI is indicated for use in surgical procedures, in which the use of stereotactic surgery may be appropriate, and where reference to rigid anatomical bony structures can be determined.

Device Description

The subject of this Traditional 510(k) is REAL INTELLIGENCE CORI XT (CORI XT), a robotic orthopedic surgical navigation and burring system. Like its predecessor, REAL INTELLIGENCE CORI (K240139), CORI XT uses established technologies of navigation via a passive infrared tracking camera. CORI XT aids the surgeon in planning the surgical implant location and in executing the surgical plan by controlling the cutting engagement of the surgical bur. CORI XT intraoperative software controls the cutting engagement of the surgical bur based on its proximity to the planned target surface. The cutting control is achieved with two modes: Exposure control adjusts the bur's exposure with respect to a guard. Speed control regulates the signal going to the motor control module. When the surgeon encroaches on a portion of bone that is not to be cut per the surgeon's plan, the robotic system will disable cutting by retracting the bur inside the guard or by limiting the speed of the drill. Alternatively, the surgeon can disable both cutting controls and operate the robotic drill as a standard navigated surgical drill.

Summary parsed at:2026-06-19 05:25:30 UTC

Predicate devices

23

K252841 references 23 predicate/reference devices

Cited as predicate

0

No later 510(k)s cite this device yet

Other submissions will appear here when they list K252841 as a predicate