Benchmed logo
Categories

TiLink-L Navigation Instruments

SurGenTec, LLC

Country / Region:United States (US)Submission type:Traditional

Product code OLO· 21 CFR 882.4560

Summary PDF

Company

United States (US)

Product code

OLO
21 CFR 882.4560

Predicate devices

4

Cited as predicate

0

Device details

FDA 510(k) registration fields

K number
K253604
Device name
TiLink-L Navigation Instruments
Country / Region
United States(US)
Product code
OLO
Device class
Class 2
Regulation number
21 CFR 882.4560
Date received
2025-11-18
Decision date
2026-03-20
Submission type
Traditional
Technology type
Stereotactic Surgery(AI inferred)
Clinical applications
Spine SurgeryNavigation System
Primary application
Navigation System
Classification source
AI classified

Indications for Use

The TiLink-L Joint Fusion System is intended for sacroiliac joint fusion for conditions including sacroiliac joint disruptions and degenerative sacroiliitis. The TiLink-L Navigation Instruments are intended to be used with the TiLink-L Joint Fusion System during surgery to assist the surgeon in precisely locating anatomical structures in either open or minimally invasive procedures. These instruments are designed for use with the Medtronic StealthStation System S8, which is indicated for any medical condition in which the use of stereotactic surgery may be appropriate, and where reference to a rigid anatomical structure, such as the pelvis or vertebra, can be identified relative to a CT or MRI based model, fluoroscopy images, or digitized landmarks of the anatomy. Fluoroscopy is intended to be used for navigating final implant placement.

Intended Use

The TiLink-L Joint Fusion System is intended for sacroiliac joint fusion for conditions including sacroiliac joint disruptions and degenerative sacroiliitis. The TiLink-L Navigation Instruments are intended to be used with the TiLink-L Joint Fusion System during surgery to assist the surgeon in precisely locating anatomical structures in either open or minimally invasive procedures. These instruments are designed for use with the Medtronic StealthStation System S8, which is indicated for any medical condition in which the use of stereotactic surgery may be appropriate, and where reference to a rigid anatomical structure, such as the pelvis or vertebra, can be identified relative to a CT or MRI based model, fluoroscopy images, or digitized landmarks of the anatomy. Fluoroscopy is intended to be used for navigating final implant placement.

Device Description

The TiLink-L Navigation Instruments include a Drill Bit, Drill Guide, and Inserter and are specifically designed to be used with the TiLink-L Joint Fusion System Implants. The TiLink-L Navigation Instruments are to be used with the NavLock Instruments and Medtronic StealthStation System S8. The TiLink-L Joint Fusion System is provided sterile (single use) and non-sterile (reusable) and the TiLink-L Navigation Instruments are manufactured from Stainless Steel per ASTM F899.

Summary parsed at:2026-06-19 04:30:47 UTC

Predicate devices

4

K253604 references 4 predicate/reference devices

Cited as predicate

0

No later 510(k)s cite this device yet

Other submissions will appear here when they list K253604 as a predicate